Evaporative Cooling Control (ECC-1)
Automatically controls sprinkler solenoids, water pumps, and fans for direct or indirect evaporative cooling systems
Phason's ECC-1 Evaporative Cooling Control monitors temperatures and efficiently and effectively controls evaporative cooling cycles according to your programmed settings.
Designed with versatility and usability in mind, the ECC-1 has two main modes of operation: 'Soaker Mode' for direct evaporative cooling or 'Mister/Fogger Mode' for indirect cooling. The ECC-1 has six relays, which can be programmed to control a combination of sprinkler solenoids, pumps, and/or single-speed fans.
With the ECC-1's active time settings, you can program sprinkling to occur only during a certain time of day. With an optional humidity sensor, you can program the ECC-1 to bypass the soaking or misting portion of the cycle when humidity levels are too high.
The LCD displays status and setting information and the four-button keypad allows you to easily scroll through information and program the control. The ECC-1's real-time clock and power-failure memory retention help save your settings and status during a power failure.
The ECC-1 is ideal for many applications, including dairy, swine, poultry, and greenhouse. All this from one powerful, efficient, and easy-to-use control!
For more information about how the ECC-1 operates, click on the ECC-1 feature sheet below.
Features
- Two automatic operation modes:
- Soaker Mode for direct evaporative cooling
- Mister/Fogger Mode for indirect evaporative cooling
- Easily-programmable temperature-based duty cycle operation
- Active/inactive time programming
- Optional humidity monitoring with high humidity bypass
- Manual control mode—for testing relays and equipment
- Six relay stages—for controlling sprinkler solenoids, water pumps, or single-speed fans
- One alarm relay—indicates power failures, probe damage, or high/low temperatures
- Thirty-foot temperature probe, extendable to 500 feet
- Information logging and display—high and low temperatures for the current and previous day, as well as total sprinkler relay ON durations for the current day and previous day
- Sixteen-character, two-line backlit LCD display—displays status and programming information
- Status lights
- Four-button keypad
- Real-time clock
- Power-failure memory protection
- Rugged enclosure (corrosion resistant, water resistant, and fire retardant)
- CSA approval
- Two-year limited warranty
Electrical ratings
| Input: Input fuse: Relays 1- 6: Alarm relay: |
120/230 VAC, 50/60 Hz 10 A, 250 VAC ABC-type ceramic 10 A at 120/230 VAC, general-purpose (resistive) 1/3 HP at 120 VAC, 1/2 HP at 230 VAC 360 W tungsten at 120 VAC 250 VA at 120 VAC for pilot-duty use 0.4 A at 125 VAC; 2 A at 30 VDC, resistive load 0.2 A at 125 VAC; 1 A at 30 VDC, inductive load |
Additional information
- ECC-1 feature sheet (PDF - 168K)
- ECC-1 user manual (PDF - 692K)
- ECC-1 reference card (PNG image - 223K)
| © 2002 to 2010 Phason Inc. All rights reserved | Last modified: |