Fan and Heater Control (FHC-1D)

Ventilation and heating control in one easy-to-use unit

The Fan and Heater Control (FHC-1D) automatically controls the temperature in a room by adjusting the speed of variable speed fans and controlling a heater interlock.

When the temperature is at the temperature set point, the FHC-1D operates the fans at the idle speed setting and the heater is off. When the temperature exceeds the set point, the FHC-1D increases the speed of the fans. When the temperature drops below the set point, the FHC-1D shuts off the fans (in shut-off mode) or operates the fans at idle speed (idle mode) and switches on the heater or heat lamps.

The FHC-1D is ideal for poultry, livestock, greenhouse, or light-industrial buildings.

Features




FHC-1D Fan and Heater Control

Electrical ratings

Input:
Variable stage: 


Variable stage fuse:
Relay:
120/230 VAC, 60 Hz
10 A at 120/230 VAC, general-purpose (resistive)
7 FLA at 120/230 VAC, PSC motor
1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor
15 A, 250 VAC ABC-type ceramic
10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC

Additional information

© 2002 to 2010 Phason Inc. All rights reserved Last modified: