Natural Ventilation Control (NVC)

Simple, effective curtain machine or actuator control

The Natural Ventilation Control (NVC) automatically controls the temperature in a room by positioning an inlet or curtain.

When the temperature is at the temperature set point, the NVC maintains the curtain position. When the temperature rises above the set point, the NVC opens the curtain for the 'open duration' and then pauses for the 'idle duration'.

After each idle duration, the NVC checks the temperature and then either opens the curtain or closes the curtain (for the preset duration) depending on the temperature.

The NVC is ideal for greenhouses and curtain-sided livestock buildings.

Features


NVC Natural Ventilation Control

Electrical ratings

Input:
Open/close relays:

Fuses:
Alarm relay:
120/230 VAC, 50/60 Hz
6 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
12 A, 250 VAC ABC-type ceramic
0.4 A at 125 VAC; 2 A at 30 VDC, resistive load
0.2 A at 125 VAC; 1 A at 30 VDC, inductive load

Additional information

 