Proportional Environment Control (PEC)

A proportional environment control with inlet capability


PEC Proportional Environment Control

The Proportional Environment Control (PEC) automatically controls the temperature in a room by operating two variable speed fans, an inlet actuator, and up to three single-speed fans or heaters.

Easy to use and program

The PEC comes with four factory-configured operating programs you can easily reconfigure for your ideal situation.

The easy-to-use keypad and menu system make the PEC one of the easiest controls to program. The PEC's advanced and powerful features are never more than a few keystrokes away.

Versatility and peace of mind

The PEC has a 30-foot temperature probe that monitors temperatures from –49 to 122°F (-45 to 50°C). For more versatility, you can connect four temperature probes together and use four-zone averaging. Temperature probes are available in 1, 6, 30, 75, or 150-foot lengths; you can extend them up to 500 feet using extension cable.

You can connect the PEC to an alarm siren or other external alarm system. Customizable alarm settings allow you to choose which alarm conditions you want to be notified about.

Common applications

Livestock applications include buildings housing calves, rabbits, goats, hogs, poultry, and turkey. In these applications, the PEC often controls ventilation in a single 20 x 40-foot or smaller room. However, the PEC is not restricted to small rooms; some customers use it to control ventilation in sow breeding rooms that are 200 feet long.

Greenhouse applications include controlling ceiling louvers, variable and single-speed fans, and heaters. Some operations use the proportional feature for misting or ground heat (water pipes).

Business and light-industrial applications include machine shops, garages, and utility sheds where customers use the PEC to control fans and inlets. The PEC exhausts heat from the room made by equipment and/or regulates the temperature as service bays open and close.

Features

Electrical ratings

Input:
Variable stages: 


Relay stages:


Inlet relays:
Alarm relay:

Fuses: (2)
120/230 VAC, 50/60 Hz
7.5 A at 120/230 VAC, general-purpose (resistive)
5 FLA at 120/230 VAC, PSC motor
1/3 HP at 120 VAC, 1/2 HP at 230 VAC, PSC motor
4.4 A at 120 VAC, 2.2 A at 230 VAC, general-purpose (resistive)
1/6 HP at 230 VAC
360 W tungsten at 120 VAC
4.4 A at 120 VAC, 2.2 A at 230 VAC, 5 A at 30 VDC
0.4 A at 125 VAC, 2.0 A at 30 VDC, resistive load
0.2 A at 125 VAC, 1.0 A at 30 VDC, inductive load
12 A, 250 VAC ABC-type ceramic

Available options

Additional information

© 2002 to 2010 Phason Inc. All rights reserved Last modified: